WanTanWanTan

Site navigation

TESTEC High-Voltage Probe

Brand
TESTEC
Origin
Germany

TESTEC high-voltage probe.

Key specification options

Type
Oscilloscope probe / Multimeter probe
Attenuation
x100 / x1000 / x1000 @10 MΩ x2000 @1 MΩ
Bandwidth
300 MHz / 40 MH (-3 dB) / DC~220 MHz and more
Rise time (typical)
≤1.2ns / ≤ 1.2ns / ≤ 9ns and more
Input impedance
100 MΩ, 5 pF / 100 MΩ, 3 pF / 900 MΩ, 2 pF and more
Input voltage
2000V (DC + Peak AC) / DC 8 kV, AC 6 kVrms, PEAK 16 kV / DC 10 kV, AC 7 kVrms, PEAK 20 kV and more

Measurement and application

High voltage measurement requires the probe, cable and receiving instrument to be considered together. The waveform, test medium, measurement location and grounding arrangement all influence the setup.

Selection and connections

Specify whether the task concerns DC, AC or pulses, and describe the test environment and instrument input. Follow the selected model instructions for installation, grounding and operation. Suitability under one set of conditions does not establish suitability under another.

Models & specifications

TESTEC High-Voltage Probe

High-voltage probe model table

TESTEC High-Voltage Probe / High-voltage probe model table
ModelTypeAttenuationBandwidthRise time (typical)Input impedanceInput voltageAccuracy
TT-HV 200 Oscilloscope probex100300 MHz≤1.2ns100 MΩ, 5 pF2000V (DC + Peak AC)DC-Accuracy : 2%
TT-HV 400 Oscilloscope probex100300 MHz≤ 1.2ns100 MΩ, 5 pF2000V (DC + Peak AC)DC-Accuracy: 2%
TT-HVP 08 Oscilloscope probex100040 MH (-3 dB)≤ 9ns100 MΩ, 3 pFDC 8 kV, AC 6 kVrms, PEAK 16 kVVDC: ±2%[+5 kV]; ±3%[+5 kV-8 kV] VAC: ±3% @ 1 kHz
TT-HVP 15 B Oscilloscope probex100040 MH (-3 dB)≤ 9ns100 MΩ, 3 pFDC 10 kV, AC 7 kVrms, PEAK 20 kVVDC: ±6%
TT-HVP 2739 Oscilloscope probex1000DC~220 MHz≤ 1.6ns900 MΩ, 2 pFDC+AC peak 39 kV, AC 27 kVrmsVDC: ±3% VAC: ±6% @ 1 kHz
TT-HVP 40 Multimeter probex1000 @10 MΩ x2000 @1 MΩ300 Hz (-3 dB)—1000 MΩDC 40 kV, AC 28 kVrms(0..300 Hz)—