WanTanWanTan

Site navigation

Danisense Zero-Flux Current Sensor

Origin
Denmark

Includes current-output, voltage-output and calibration-winding configurations. Compare current range, aperture and output interface.

Key specification options

Current range
72A
Product dimensions (mm)
65x32x60
Aperture (mm)
-
Conversion ratio
1:250,500,1000
Output port
-
Notes
Programmable

Measurement and application

A current sensor forms part of a system that also includes the conductor, power supply and acquisition equipment. Planning these connections together helps define the mounting position, signal path and method of reading the current measurement.

Selection and connections

Confirm whether the conductor can pass through the sensor or requires an opening structure. Then check output type, power supply and acquisition interface. Current output and voltage output versions require their respective connection arrangements.

Related models & specifications

Danisense Zero-Flux Current Sensor

0~600A

Danisense Zero-Flux Current Sensor / 0~600A
Model (0-1KA)Current rangeProduct dimensions (mm)Aperture (mm)Conversion ratioOutput portNotes
PCB Mount
DP50IP-B 72A65x32x60-1:250,500,1000-Programmable
Faston connection
DC200IF 300A80x61.5x41.5201:1000Faston—
DSUB current output
DS50ID 150A121.4x107.5x44.527.61:500DSUB9—
DT50ID 75A76×64.5×3520.71:500DSUB9—
DT100ID 150A76×64.5×3520.71:500DSUB9—
DT200ID 285A76×64.5×3520.71:500DSUB9—
DS200ID 370A121.4x107.5x44.527.61:500DSUB9—
DS300ID 500A121.4x107.5x44.527.61:1000DSUB9—
DS400ID 600A121.4x107.5x44.527.61:2000DSUB9—
DS600ID 1000A121.4x107.5x44.527.61:1500DSUB9—
DQ500ID 800A104x106x4728.11:1750DSUB9—
DQ600ID 1000A104x106x4728.11:1500DSUB9—
DQ640ID-B 640A104x106x4728.140A-640ADSUB920A/Step adjustable
DQ600ID-P1300 1300A104x106x4728.11:1500DSUB91300A peak
Calibration winding in DSUB
DS200ID-CD100 370A121.4×107.5×44.527.61:500DSUB9—
DS200ID-CD1000 370A121.4×107.5×44.527.61:500DSUB9—
DS600ID-CD100 1000A121.4×107.5×44.527.61:1500DSUB9—
BNC voltage output (2 ppm/K)
DS50UB-1V 150A121.4x107.5x44.527.61V:50ADSUB9/BNC—
DS50UB-10V 55A121.4x107.5x44.527.610V:50ADSUB9/BNC—
DS200UB-1V 300A121.4x107.5x44.527.61V:200ADSUB9/BNC—
DS200UB-10V 220A121.4x107.5x44.527.610V:200ADSUB9/BNC—
DS300UB-1V 500A121.4x107.5x44.527.61V:300ADSUB9/BNC—
DS300UB-10V 330A121.4x107.5x44.527.610V:300ADSUB9/BNC—
DS400UB-1V 600A121.4x107.5x44.527.61V:400ADSUB9/BNC—
DS400UB-10V 440A121.4x107.5x44.527.610V:400ADSUB9/BNC—
DW500UB-2V 750A92x130x42252V:500ABNC—
DS600UB-1V 900A121.4×107.5×44.527.61V/600ADSUB9/BNC—
DS600UB-10V 660A121.4×107.5×44.527.610V/600ADSUB9/BNC—

600A~3000A

Danisense Zero-Flux Current Sensor / 600A~3000A
Model (600A~3KA)Current rangeProduct dimensions (mm)Aperture (mm)Conversion ratioOutput portNotes
DSUB current output
DN1000ID 1500A132×112,2×43,941,21:1500DSUB—
DM1200ID 1800A178.6x174x53451:1500DSUB9—
DL2000ID 3000A239.8x230x82681:1500DSUB9—
Calibration winding BNC
DL2000ID-CB100 3000A239.8x230x82681:1500DSUB/BNCCalibration 100turns
Calibration winding DSUB
DM1200ID-CD3000 1500A178,6x174x53451:1500DSUBCalibration 3000 turns
DL2000ID-CD100 3000A239.8x230x82681:1500DSUBCalibration 100turns
BNC voltage output
DS1000UB-10V 1100A121.4×107.5×44.527.610V:1000 ADSUB/BNC—
DM1200UB-1V 1800A178.6x174x53451V:1200ADSUB9/BNC—
DM1200UB-10V 1320A178.6x174x53451V:120ADSUB9/BNC—
DL2000UB-1V 3000A239.8x230x82681V:2000ADSUB9/BNC—
DL2000UB-10V 3000A239.8x230x82681V:200ADSUB9/BNC—

Above 3000A

Danisense Zero-Flux Current Sensor / Above 3000A
ModelCurrent rangeProduct dimensions (mm)Aperture (mm)Conversion ratioOutput portNotes
Current output
DR5000IM 8000A420x325x1221501:25004mm banana plug—
DR10000IM 11000A420x325x1221401:25004mm banana plug—
Voltage output
DR5000UX-10V/5000A 420x325x1221501V:500A3 pin XLR MiniIncludes 2m output cable
DR5000UX-10V_7500A 8000A420x325x1221501.333V:KA3pin XLRMiniIncludes 2m output cable
DR10000UX-10V 11000A420x325x1221401V:1KA3pin XLRMiniIncludes 2m output cable